The Click PLC can communicate to remote I/O (input and output) controller modules using the Modbus protocol for communications. The BX-MBIO provides both Modbus RTU and Modbus TCP interfaces for remote IO. Modbus RTU is a serial communication and Modbus TCP is an Ethernet communication. More information can be obtained on our website. This includes all of the links mentioned in this video. https://accautomation.ca/click-plc-to-modbus-tcp-rtu-remote-io-controller-bx-mbio Modbus RTU is supported over an RS-485 serial connection. Modbus TCP is supported over an Ethernet connection. They function as listening/replying devices (slave, server) and can connect with any mastering (master, client) device that communicates using the Modbus protocol. Previously we looked at the BX-MBIO Modbus RTU TCP Remote IO Controller wiring and configuration. Modbus RTU TCP Remote IO Controller BX-MBIO https://accautomation.ca/modbus-rtu-tcp-remote-io-controller-bx-mbio - BX-MBIO Hardware Video https://youtu.be/cqP78u4YVGQ - BX-MBIO Powering and Configuring Video https://youtu.be/XIsL86ou44U We will connect the Click Ethernet PLC to the Modbus remote IO. This will be done using the Modbus TCP and Modbus RTU protocol. Ethernet and serial RS485 communication to the BX-MBIO unit will be the media. The BX-MBIO remote I/O expansion units feature the following: • RJ45 Ethernet port for communications via Modbus TCP • RS485 serial port for communications via Modbus RTU • Supports up to 8 additional Expansion Modules (Add the discrete or analog I/O you require) • AC and DC powered units available • AC powered units include an integral 24VDC auxiliary output power supply • Power connector and serial port connector included Let's get started. Previously we discussed: Click PLC Installing the Software https://accautomation.ca/click-plc-installing-the-software/ Click PLC Establish Communication https://accautomation.ca/click-plc-establish-communication/ Click PLC Numbering System and Addressing https://accautomation.ca/click-plc-numbering-system-and-addressing Click PLC Timers and Counters https://accautomation.ca/click-plc-timers-and-counters Click PLC Program Control Instructions https://accautomation.ca/click-plc-program-control-instructions Click PLC Shift Register Instruction https://accautomation.ca/click-plc-shift-register-instruction Click PLC Drum Instruction https://accautomation.ca/click-plc-drum-instruction Click PLC Send and Receive Instructions https://accautomation.ca/click-plc-send-and-receive-instructions Click PLC AdvancedHMI Communication https://accautomation.ca/click-plc-advancedhmi-communication Modbus RTU Click PLC Master to BRX PLC Slave Communication https://accautomation.ca/modbus-rtu-click-plc-master-to-brx-plc-slave-communication Video https://youtu.be/CIsj-Xppoog Click PLC - Update Firmware https://accautomation.ca/click-plc-update-firmware Video https://youtu.be/1X_kw4Rhokw Click PLC HMI Rotary Encoder Dial Input https://accautomation.ca/click-plc-hmi-rotary-encoder-dial-input Video https://youtu.be/mix9k2RTdII High-Speed Counter - Part 1 https://accautomation.ca/click-plc-high-speed-counting-part-1 High-Speed Count Mode Video https://youtu.be/P3l34unyAyU Interval Measurement Mode Video https://youtu.be/-t8JSKruilE Duration Measurement Mode Video https://youtu.be/znF6PRwGq-Y Frequency Measurement Mode Video https://youtu.be/m0I9P5AoFqE Click PLC High-Speed Counter - Part 2 https://accautomation.ca/click-plc-high-speed-counting-part-2 External Interrupt Mode https://youtu.be/UxFffVddUt4 Pulse Catch Mode https://youtu.be/2H0zwul1X3o Filter Pulse Mode https://youtu.be/FNbYAkBwIsQ Frequency Measurement and High-Speed Count Mode https://youtu.be/qV3jgRszghE Analog Dusk to Dawn Program https://accautomation.ca/click-plc-analog-dusk-to-dawn-program https://youtu.be/JlxTBlk6IJY PID using Factory IO https://accautomation.ca/click-plc-pid-using-factory-io https://youtu.be/JGB9e__MWPc PID Instruction and Autotuning using Factory IO https://accautomation.ca/click-plc-pid-instruction-and-autotuning-using-factory-io https://youtu.be/QoMw1SGW-gA Logging Data with Time and Date Stamp https://accautomation.ca/click-plc-logging-data-with-time-and-date-stamp https://youtu.be/CQ5xa5UZPng The entire Click PLC series can be found at this URL: https://accautomation.ca/series/click-plc/ There are several reasons why we are using the Click PLC. Here are just a few. - Investment is low for the hardware and the software is free - Standalone PLC with built-in I/O - Communication ability - Ethernet Port, RS232, RS485 - support for protocols such as Modbus RTU, Modbus TCP, etc. - Ability to expand the system with a variety of modules including RTD and Thermocouple inputs directly. https://www.accautomation.ca
Show More

Comments

loading text loading
loading text loading
loading text
loading text loading
loading text
loading text loading
loading text
loading text loading
loading text