Construction & Maintenance
Manufacturing
Click PLC to Modbus TCP RTU Remote IO Controller BX MBIO
287 views
·
Oct 13, 2022
The Click PLC can communicate to remote I/O (input and output) controller modules using the Modbus protocol for communications. The BX-MBIO provides both Modbus RTU and Modbus TCP interfaces for remote IO. Modbus RTU is a serial communication and Modbus TCP is an Ethernet communication.
More information can be obtained on our website. This includes all of the links mentioned in this video. https://accautomation.ca/click-plc-to-modbus-tcp-rtu-remote-io-controller-bx-mbio
Modbus RTU is supported over an RS-485 serial connection. Modbus TCP is supported over an Ethernet connection. They function as listening/replying devices (slave, server) and can connect with any mastering (master, client) device that communicates using the Modbus protocol.
Previously we looked at the BX-MBIO Modbus RTU TCP Remote IO Controller wiring and configuration.
Modbus RTU TCP Remote IO Controller BX-MBIO
https://accautomation.ca/modbus-rtu-tcp-remote-io-controller-bx-mbio
- BX-MBIO Hardware Video
https://youtu.be/cqP78u4YVGQ
- BX-MBIO Powering and Configuring Video
https://youtu.be/XIsL86ou44U
We will connect the Click Ethernet PLC to the Modbus remote IO. This will be done using the Modbus TCP and Modbus RTU protocol. Ethernet and serial RS485 communication to the BX-MBIO unit will be the media.
The BX-MBIO remote I/O expansion units feature the following:
• RJ45 Ethernet port for communications via Modbus TCP
• RS485 serial port for communications via Modbus RTU
• Supports up to 8 additional Expansion Modules (Add the discrete or analog I/O you require)
• AC and DC powered units available
• AC powered units include an integral 24VDC auxiliary output power supply
• Power connector and serial port connector included
Let's get started.
Previously we discussed:
Click PLC Installing the Software
https://accautomation.ca/click-plc-installing-the-software/
Click PLC Establish Communication
https://accautomation.ca/click-plc-establish-communication/
Click PLC Numbering System and Addressing
https://accautomation.ca/click-plc-numbering-system-and-addressing
Click PLC Timers and Counters
https://accautomation.ca/click-plc-timers-and-counters
Click PLC Program Control Instructions
https://accautomation.ca/click-plc-program-control-instructions
Click PLC Shift Register Instruction
https://accautomation.ca/click-plc-shift-register-instruction
Click PLC Drum Instruction
https://accautomation.ca/click-plc-drum-instruction
Click PLC Send and Receive Instructions
https://accautomation.ca/click-plc-send-and-receive-instructions
Click PLC AdvancedHMI Communication
https://accautomation.ca/click-plc-advancedhmi-communication
Modbus RTU Click PLC Master to BRX PLC Slave Communication
https://accautomation.ca/modbus-rtu-click-plc-master-to-brx-plc-slave-communication
Video
https://youtu.be/CIsj-Xppoog
Click PLC - Update Firmware
https://accautomation.ca/click-plc-update-firmware
Video
https://youtu.be/1X_kw4Rhokw
Click PLC HMI Rotary Encoder Dial Input
https://accautomation.ca/click-plc-hmi-rotary-encoder-dial-input
Video
https://youtu.be/mix9k2RTdII
High-Speed Counter - Part 1
https://accautomation.ca/click-plc-high-speed-counting-part-1
High-Speed Count Mode Video
https://youtu.be/P3l34unyAyU
Interval Measurement Mode Video
https://youtu.be/-t8JSKruilE
Duration Measurement Mode Video
https://youtu.be/znF6PRwGq-Y
Frequency Measurement Mode Video
https://youtu.be/m0I9P5AoFqE
Click PLC High-Speed Counter - Part 2
https://accautomation.ca/click-plc-high-speed-counting-part-2
External Interrupt Mode
https://youtu.be/UxFffVddUt4
Pulse Catch Mode
https://youtu.be/2H0zwul1X3o
Filter Pulse Mode
https://youtu.be/FNbYAkBwIsQ
Frequency Measurement and High-Speed Count Mode
https://youtu.be/qV3jgRszghE
Analog Dusk to Dawn Program
https://accautomation.ca/click-plc-analog-dusk-to-dawn-program
https://youtu.be/JlxTBlk6IJY
PID using Factory IO
https://accautomation.ca/click-plc-pid-using-factory-io
https://youtu.be/JGB9e__MWPc
PID Instruction and Autotuning using Factory IO
https://accautomation.ca/click-plc-pid-instruction-and-autotuning-using-factory-io
https://youtu.be/QoMw1SGW-gA
Logging Data with Time and Date Stamp
https://accautomation.ca/click-plc-logging-data-with-time-and-date-stamp
https://youtu.be/CQ5xa5UZPng
The entire Click PLC series can be found at this URL:
https://accautomation.ca/series/click-plc/
There are several reasons why we are using the Click PLC. Here are just a few.
- Investment is low for the hardware and the software is free
- Standalone PLC with built-in I/O
- Communication ability - Ethernet Port, RS232, RS485 - support for protocols such as Modbus RTU, Modbus TCP, etc.
- Ability to expand the system with a variety of modules including RTD and Thermocouple inputs directly.
https://www.accautomation.ca
Show More
Show LessComments
loading text loading
loading text loading
loading text
loading text loading
loading text
loading text loading
loading text
loading text loading
loading text