Productivity 1000 Series PLC Modbus ASCII Protocol

1K views · Oct 13, 2022
Visit Channel:publisher-humix
More information can be obtained on our website. This includes all of the links mentioned in this video. https://accautomation.ca/productivity-1000-series-plc-modbus-ascii-protocol Modbus is a communication method used for transmitting information over serial lines between electronic devices. The device requesting the information is called the Modbus Master (Client) and the devices supplying information are Modbus Slaves (Servers). This protocol was originally developed by Modicon systems. Modbus protocol comes in basically three different types. Ethernet (Modbus TCP) or Serial (Modbus RTU or Modbus ASCII). Modbus TCP and Modbus RTU come as standard protocols in the productivity series of PLCs. We will connect the Productivity 1000 PLC to a Solo process temperature controller. This will be done using the Modbus ASCII protocol over serial RS485 communication wire. (Media) The present and set values (PV / SV) will be read from the Solo controller and the set value will be written when required. Let's get started. Here are some previous posts in this Productivity 1000 PLC Series. A full list can be obtained at the following location: https://accautomation.ca/series/productivity-1000-plc/ Installing the Software https://accautomation.ca/productivity-1000-series-plc-installing-the-software https://youtu.be/gh5X7_EeCdg Establishing Communication https://accautomation.ca/productivity-1000-series-plc-establishing-communication https://youtu.be/HWtN189JLgI First Program https://accautomation.ca/productivity-1000-series-plc-first-program https://youtu.be/txr_wfd7y2w Monitoring and Testing the Program https://accautomation.ca/productivity-1000-series-plc-monitoring-and-testing-the-program https://youtu.be/o9gdrrEMexw Online Editing and Debug Mode https://accautomation.ca/productivity-1000-series-plc-online-editing-and-debug-mode https://youtu.be/D-sDKMnw1gQ Numbering Systems and Tag Database https://accautomation.ca/productivity-1000-series-plc-numbering-systems-and-tag-database https://youtu.be/s-TAWomBeIs Array Functions Part 1 https://accautomation.ca/productivity-1000-series-plc-array-functions-part-1 https://youtu.be/8ITrEWeBgPc Array Functions Part 2 https://accautomation.ca/productivity-1000-series-plc-array-functions-part-2 https://youtu.be/jO0z6-MpGqE Array Functions Part 3 https://accautomation.ca/productivity-1000-series-plc-array-functions-part-3 https://youtu.be/8M3LV-XihNo Program Control https://accautomation.ca/productivity-1000-series-plc-program-control https://youtu.be/QPrIzxDq16A Data Logger https://accautomation.ca/productivity-1000-series-plc-data-logger https://youtu.be/mM1zbbX7zVg Web Server https://accautomation.ca/productivity-1000-series-plc-web-server https://youtu.be/ZuZd3lqp87c Modbus RTU Serial Communication https://accautomation.ca/productivity-1000-series-plc-modbus-rtu-serial-communication https://youtu.be/6LqbOyrWQ88 Modbus TCP Ethernet Communication https://accautomation.ca/productivity-1000-series-plc-modbus-tcp-ethernet-communication https://youtu.be/CEyIJUmpqcI AdvancedHMI Modbus TCP Ethernet Communication https://accautomation.ca/productivity-1000-series-plc-advancedhmi-modbus-tcp-ethernet-communication https://youtu.be/derBxqOc-a8 Email Text Communication https://accautomation.ca/productivity-1000-series-plc-email-and-text-communication https://youtu.be/dEnL5tNbXmM Productivity 1000 PLC to Stride Field IO Modbus TCP https://accautomation.ca/productivity-1000-plc-to-stride-field-io-modbus-tcp https://youtu.be/Nu5HfYsDidE Productivity 1000 PLC to Modbus TCP RTU Remote IO Controller BX-MBIO https://accautomation.ca/productivity-1000-plc-to-modbus-tcp-rtu-remote-io-controller-bx-mbio https://youtu.be/46J6DFGAnCQ There are several reasons why we are using the Productivity 1000 Series Controller. Here are just a few. - 50MB user memory - Can handle very complex applications easily. - 4 built-in communication ports – Easy connectivity to your network. - Data logging up to 32 GB on a microSD card - Add up to 8 IP modules to communicate to your field sensors. This will give you a total of 128 discrete IO points or 32 analog IO channels. - Free Software and 30 days of free training with every CPU from Automation Direct. - Interactive PLC Configuration Tool - Tag Names - Auto-discovery IO – Physical I/O tags will be generated based on each module’s position in the base. - I/O Modules have QR codes under the wiring cover. This can be scanned so you can have the latest specifications/wiring diagrams for the module. - Limitless PID – Autotuning – Individual or Cascade Mode - etc - Web Server and Mobile Access - Advanced Software instruction set The Productivity 1000 series of programmable logic controllers currently has all of these features built into the P1-540 CPU. This CPU (Central Processing Unit) is also known as MPU (Multi-Processing Units) because of the communication capabilities. https://www.accautomation.ca
Show More

Comments

loading text loading
loading text loading
loading text
loading text loading
loading text
loading text loading
loading text
loading text loading
loading text