Engineering & Technology
Industrial Materials & Equipment
Manufacturing
BRX Do-More PLC Modbus ASCII Protocol
3K views
·
Oct 13, 2022
We will now look at the do more plc modbus ascii protocol communication. This will be done through PLC ladder logic sending ASCII characters out the serial port.
More information can be obtained on our website. This includes all of the links mentioned in this video.
https://accautomation.ca/brx-do-more-plc-modbus-ascii-protocol
Modbus is a communication method used for transmitting information over serial lines between electronic devices. The device requesting the information is called the Modbus Master (Client) and the devices supplying information are Modbus Slaves (Servers). This protocol was originally developed by Modicon systems.
Modbus protocol comes in basically three different types. Ethernet (Modbus TCP) or Serial (Modbus RTU or Modbus ASCII). Modbus TCP and Modbus RTU come as standard protocols in the BRX Do-More series of PLCs.
We will connect the BRX Do-More PLC to a Solo process temperature controller. This will be done using the Modbus ASCII protocol over serial RS485 communication wire. (Media) The present and set values (PV / SV) will be read from the Solo controller and the set value will be written when required. Let's get started.
The entire BRX Series PLC can be found at the following location:
https://accautomation.ca/series/brx-do-more-plc/
Here are some of the individual posts with video links:
Installing the Software
https://accautomation.ca/brx-plc-installing-the-software
https://youtu.be/iFI1ebP8Zkk
Establishing Communication
https://accautomation.ca/brx-plc-establishing-communication
https://youtu.be/shU5g8MA8VM
Numbering Systems and Addressing
https://accautomation.ca/brx-plc-numbering-systems-and-addressing
https://youtu.be/-GiKnIDycKY
First Program
https://accautomation.ca/brx-plc-first-program
https://youtu.be/ANSNhdlm_Ao
Online Editing and Debug Mode
https://accautomation.ca/brx-plc-online-editing-and-debug-mode
https://youtu.be/77pemu3zXrE
Timers
https://accautomation.ca/brx-plc-timers
https://youtu.be/0qU9kgunPi4
Serial Communication – Modbus RTU to Solo Process Temperature Controller
https://accautomation.ca/brx-plc-serial-communication-modbus-rtu-to-solo-process-temperature-controller
https://youtu.be/PndrIfBImGQ
Data Logging
https://accautomation.ca/brx-plc-data-logging
https://youtu.be/OBv7XJ9mJeA
Email – Text SMS Messaging Gmail
https://accautomation.ca/brx-plc-email-text-sms-messaging-gmail
https://youtu.be/0L74qOwwWAE
Secure Email Communication
https://youtu.be/hhVawCL3ztU
AdvancedHMI Communication – Modbus TCP
https://accautomation.ca/brx-plc-advancedhmi-communication-modbus-tcp
https://youtu.be/1TjsdLwTKM0
PID with PWM Output
https://accautomation.ca/brx-plc-pid-with-pwm-output
https://youtu.be/wUNSv-0e5Rc
PID Ramp Soak Profile
https://accautomation.ca/brx-plc-pid-ramp-soak-profile
https://youtu.be/RVOnDwFi1cc
BRX Do-More Simulator MQTT Publish-Subscribe
https://accautomation.ca/brx-do-more-simulator-mqtt-publish-subscribe
https://youtu.be/assMcr7caa8
BRX Do-More PLC MQTT Communications
https://accautomation.ca/brx-do-more-plc-mqtt-communications
https://youtu.be/Tjtrxh1K-b4
BRX Do-More PLC to Stride Field IO Modbus TCP
https://accautomation.ca/brx-do-more-plc-to-stride-field-io-modbus-tcp
https://youtu.be/y4K5OwRBFB8
BRX Do-More PLC Ethernet Remote IO Controller BX-DMIO
https://accautomation.ca/brx-do-more-plc-ethernet-remote-io-controller-bx-dmio
Modbus RTU TCP Remote IO Controller BX-MBIO
https://accautomation.ca/modbus-rtu-tcp-remote-io-controller-bx-mbio
BRX Do-More PLC to Modbus TCP RTU Remote IO Controller BX-MBIO
https://accautomation.ca/brx-do-more-plc-to-modbus-tcp-rtu-remote-io-controller-bx-mbio
https://youtu.be/IjTLE2-azHk
There are several reasons why we are using the BRX Series Controller. Here are just a few.
- Standalone PLC with built-in I/O
- Built-in Data Logging
- Communication ability - Ethernet Port, RS232, RS485, USB - support for protocols such as Modbus RTU, Modbus TCP, ASCII, K-sequence (DirectLOGIC users), Custom Protocols (ASCII over serial, TCP or UDP over Ethernet)
- Built-in Analog input and output
- Integrated motion control
- High-speed counters
- Powerful instruction set (Video of Instructions in software)
- Ability to expand the system with a variety of modules
- Part of the Do-More series of PLCs which use the same free software. (Do-More Designer)
- Integrated simulator in the software capable of external communications for testing
The BRX series of programmable logic controllers consist of four different units. They differ depending on the Inputs and Outputs built into the unit and if it has the ethernet port.
No I/O Micro PLC unit – (BX ME)
10 Point Micro PLC unit – (BX 10/10E)
18 Point Micro PLC unit - (BX 18/18E)
36 Point Micro PLC unit - (BX 36/36E)
These CPUs (Central Processing Units) are also known as MPU (Multi-Processing Units) because of the communication capabilities.
https://www.accautomation.ca
Show More
Show LessComments
loading text loading
loading text loading
loading text
loading text loading
loading text
loading text loading
loading text
loading text loading
loading text