The share link has been copied to clipboard
Enterprise Technology
Software

MOSAIC Safety Controller Emergency Stop

1K views · Oct 13, 2022
Visit Channel:publisher-humix
We will now look at the Safety Emergency Stop to our MOSAIC Controller. The MOSAIC Modular Safety Integrated Controller can be programmed for your safety control application. Steps to programming our MOSAIC include writing the program, verification, simulation, downloading, and monitoring. We will be looking at the E-STOP instruction part of our program. Our first program included writing, verifying, simulating, and monitoring our MOSAIC Safety emergency stop switch and status indication. (feedback) We will now modify our E-STOP in our circuit and discuss redundancy, short circuit protection, and manual reset. Let's get started. More information can be obtained on our website. This includes all of the links mentioned in this video. https://accautomation.ca/mosaic-safety-controller-emergency-stop Previously we have discussed the following in our MOSAIC Safety Controller: System Hardware https://accautomation.ca/mosaic-safety-controller-system-hardware System Hardware Un-boxing Video https://youtu.be/P9OGuZgbPbc System Hardware Powering Up Video https://youtu.be/nRMir2Ov_zc Installing the Software (MSD) https://accautomation.ca/mosaic-safety-controller-installing-the-software-msd https://youtu.be/ILMe7dW2zm4 First Program Part 1 https://accautomation.ca/mosaic-safety-controller-first-program-part-1 https://youtu.be/ZQIYG9lvEf0 First Program Part 2 https://accautomation.ca/mosaic-safety-controller-first-program-part-2 https://youtu.be/4x9aerOd100 Documentation https://accautomation.ca/mosaic-safety-controller-documentation https://youtu.be/BBEBN8S_XeU ReeR MOSAIC Safety Controller (Automation Direct) Features: - Mosaic is a safety hub able to manage all safety functions of machinery or a plant - Configurable and scalable - Allows cost reductions and minimal wiring - Mosaic can manage safety sensors and signals such as - light curtains - photocells, - laser scanners - emergency stops - electromechanical switches - guard-lock safety door switches - magnetic switches - safety mats and edges - two-hands controls - hand grip switches - encoders - proximities for safety speed control ReeR MOSAIC Safety Controller (Automation Direct) Advantages: - Reduces the number of devices and wiring used and overall size of the project Speeding-up control panel construction - Allows tamper-proof system configurations - All logic is configured through a graphic interface (no more laborious wiring is needed as with traditional solutions) - The lower number of electromechanical components also means a better performance level and a higher safety level - Project report provides the actual values of PFH, DCavg and MTTFd according to EN 13849-1 and EN 62061 https://www.accautomation.ca
Show More

Comments

loading text loading
loading text loading
loading text
loading text loading
loading text
loading text loading
loading text
loading text loading
loading text